* Update additional files
* The LineColor and LineWidth properties are removed from Text objects.
* Arrow properties are added by the ViewProviderDraftAnnotation class only. This avoids code duplication.
* gui_annotationstyleeditor.py fix except
* view_draft_annotation.py fix except
---------
Co-authored-by: Roy-043 <info@b-k-g.nl>
Co-authored-by: Roy-043 <70520633+Roy-043@users.noreply.github.com>
* Fix various typos
Found via codespell
* [pre-commit.ci] auto fixes from pre-commit.com hooks
for more information, see https://pre-commit.ci
---------
Co-authored-by: pre-commit-ci[bot] <66853113+pre-commit-ci[bot]@users.noreply.github.com>
PR to make the handling of the mentioned inputs consistent with that of the X, Y and Z inputs: check for in-command shortcuts. and select only the numerical portion of the text on focus change.
* [BIM] Fix attribute error when user deletes the BimViewArea dock widget
* [BIM] Fix Attribute Error for both Qt5 and Qt6
* Update src/Mod/BIM/bimcommands/BimViews.py
---------
Co-authored-by: Chris Hennes <chennes@pioneerlibrarysystem.org>
* [ArchWindow] Bug-fix Changing Sill _&_ SketchArch Support Sill Property
1. Bug found in https://github.com/FreeCAD/FreeCAD/pull/21005 (Allow changing Sill parameter)
self.baseSill
self.basePos :
- need to be restored as 'initial' settings in onDocumentRestored() as corresponding codes in onChanged() does upon object creation
2. ArchWindow with SketchArch add-on to support above 'Allow changing Sill paramemeter' feature
- Update to ArchWindow following groundworks in https://github.com/FreeCAD/FreeCAD/pull/21568/
* [ArchWindow] Bug-fix Changing Sill _&_ SketchArch Support Sill Property (rev)
https://github.com/FreeCAD/FreeCAD/pull/21261
Historically, the normal of a Window object was deduced by the orientation of the Base Sketch and hardcoded in the Normal property.
Now with the new AutoNormalReversed property/flag (above PR), set True as default, the auto Normal previously in opposite direction to is now consistent with that previously hardcoded.
With the normal set to 'auto', window object would not suffer weird shape if the Base Sketch is rotated by some reason.
The Normal property is set to 'auto' (0,0,0) default following the above PR.
https://github.com/FreeCAD/FreeCAD/pull/21005
BIM: Allow changing Sill parameter in Properties for Window #21005
Ground work is added to support Window augmented by SketchArch Parametric Placement feature (PR to ArchWindow.py to be submitted separately)
Fixes: #7387.
See comment: https://github.com/FreeCAD/FreeCAD/issues/7387#issuecomment-2915599566
PR to change the base object of BezCurve, BSpline and Wire to `Part::FeaturePython`. This will only affect new objects. So code will have to also keep handling the old object type (`Part::Part2DObjectPython`).
The modification of BimPreflight.py needs to be verified. The steps in the old code lacked logic IMO. But I may have misunderstood.
* BIM: Use checkbox in model tree for Activation/Deactivation of WP
* BIM: Set active object after deactivating current object if it exists
Currently we can get into a scenario where user can activate two working
planes, one after another. For example, Level, and then Level001. If
they activate both, and then deactivate Level001, working plane switches
back to Level. But, we didn't set the object as the active one, so user
didn't have clear information that they can deactivate it, only the
working plane was switching it.
So this patch sets the object as the active one, if it exists.
* BIM: Add support for deactivation active object to BIM Views Tree
As the title says - it adds the checkbox that's similarly done in Part
workbench, so user can select/deselect the item and if they had previous
active object, it will also fall back to the previous object.
Also, moved out part of the common logic from ArchBuildingPart and
BimViews to utils.
* BIM: Handle correct context on activating WP for NativeIFC/BIM
* BIM: Remove redundant logic from BIM Views upon double click
As all of the logic is being handled now in `activate` function in
BimViews, this logic is redundant
* BIM: Rename button for taskbar and BIM Views from Activate to Active
This patch introduces a few things:
- changes Activate button to be first in the list
- puts it in bold text, also adding (Default) to point it is default
action
- removes all of the hiding logic upon double click and leaving Activate
by default to be called after double-clicking a BuildingPart
Currently, for both Help and BIM Views panels we can get a traceback
about incorrect casting if we move the panel.
This is because the QFlag of DockWidgetArea that is being passed, as it is not
able to be parsed down to an int. Most probably some historical change
either in Qt or FC.
This error also caused to not write current BIM Views/Help panel setup
to config, resulting in the position being resetted every run.
Currently we can assign quantities to a BIM object, but upon exporting
quantities are not visible in the IFC file.
This was because we didn't have a correct mapping to weight property.
`App::PropertyWeight" basically doesn't exist, so this patch changes it
to `App::PropertyMass`, as it is the same. The incorrect mapping
resulted in a traceback, which in turn resulted in missing a big part of
additional processing for the properties, which resulted in
`writeQuantities` checking for non-existent IfcData in the object.
As the title says, if user selects `OK` button and has no Classification
selected (which can happen only if the list is empty I think), then they
get a traceback since we're trying to access list of selections
directly.
So this patch adds a small patch to close the form if user has pressed
`OK` button and did not select anything.
Improvement to User Interactive Experience:
- The Window Interactive Tool would check if SketchArch-addon is enabled by user, i.e. if ArchSketckLock is checked.
- If not, the conventional creation behaviour is used, SketchArch properties would not be added to Window object.
- It also check if Base of Wall is ArchSketch or not.
Github Discussion:
- https://github.com/paullee0/FreeCAD_SketchArch/issues/27#issuecomment-2837652351
User has no possibility to change Sill parameter upon adding Window, it
is only possible while creating Window for the first time.
So this patch adds this parameter, and changing it moves the *BASE*
coordinate of the object in Z direction.
Currently if user selects an item and does `Isolate` operation on it in
BIM, everything is being hidden if the item was inside another container
(like Building).
This is because we are prioritizing on hiding parents of current object
if they are not the selected ones, which is causing the child of the
parent to be hidden as well (duh).
So, this patch fixes isolate method to hide all other parents and their
childs. If they are not a parent of our child under selection -> hide
them and proceed further. If we are processing parent of our selection,
just hide anything on current level that is not our selection while
leaving parent intact.
Currently there's no option for selecting active working plane other
than selecting `DoubleClickActivates` property on a BIM Level.
So, this patch adds an additional button for the submenu that BIM Views
provides - to activate working plane of the selected item.
Fixes#21179.
This PR uses the built-in solution to close the task panel.
I was not aware of this feature before. My 2 previous PRs related to the closing of task panels, #20719 and #21073, will (largely) have to be reverted/redone in favor of this solution.
So, currently, if we use Vertical/Horizontal Dimension which is
constrained in one direction vector, upon `Continue`, the direction
vector is not being preserved.
The cause of that is that everytime we recall the command in Continue
Mode, we also call base class' `Activated` method, which in turn calls
`finish()` if we have already initialized an active Draft command. This
doesn't happen during first usage of the command, because this variable
is not yet populated, but upon second (and next) runs it is. In turn,
this causes to call `finish()`, and clean up the direction vector. So,
in essence, we are specifying the vector and cleaning it every
"Continue" run.
So, as a solution, just move the direction vector as an argument to
populate super class with it, and do that after super class' `Activated()`
call, so it won't get cleaned up in `finish()`.
Co-authored-by: Yorik van Havre <yorik@uncreated.net>
Fixes#17952.
This PR is a continuation of #20719.
It mainly involves adding `self.doc`. This new attribute is then also used in the rest of the modified classes. In some cases code was slightly reordered for consistency.
The `_finish_command_on_doc_close` function has been modifief to also handle `Gui.Snapper.ui.escape` and the code in gui_arcs.py has been updated accordingly.
Additionally:
Removed the `done` and `spacedone` variables in BimWall.py by tweaking the code.
* BIM: add tooltip info on how to insert the view on a particular page
* Fix typo
* BIM: split tooltip comment for better code readability
Co-authored-by: Benjamin Nauck <benjamin@nauck.se>
---------
Co-authored-by: Benjamin Nauck <benjamin@nauck.se>