- especially don't hardcode the choly solver that fails quickly for finer meshes
- setting sorcg as default since it shows the best performance with the cantilever tests
- since we use consistently SI units (as recommended my the Elmer forum), we need to scale the input mesh (we use ElmerGrid that has an option fur this purpose)
- Since the result will be in the scaled mesh, we need to scale it back
With this PR, one gets now correct result independent of
- the used unit scheme
- the simulation type (electrical or thermo-mechanical)
- fixes#6604
as it was, Elmer was almost unusable because most values were input with wrong units to Elmer.
Elmer uses pure SI units
ToDo: fix the still wrong Vacuum permittivity
Found via `codespell -q 3 -L aci,ake,aline,alle,alledges,alocation,als,ang,anid,apoints,ba,beginn,behaviour,bloaded,bottome,byteorder,calculater,cancelled,cancelling,cas,cascade,centimetre,childs,colour,colours,commen,connexion,currenty,dof,doubleclick,dum,eiter,elemente,ende,feld,finde,findf,freez,hist,iff,indicies,initialisation,initialise,initialised,initialises,initialisiert,inout,ist,kilometre,lod,mantatory,methode,metres,millimetre,modell,nd,noe,normale,normaly,nto,numer,oder,ontop,orgin,orginx,orginy,ot,pard,parms,pres,programm,que,recurrance,rougly,seperator,serie,sinc,strack,substraction,te,thist,thru,tread,uint,unter,vertexes,wallthickness,whitespaces -S ./.git,*.po,*.ts,./ChangeLog.txt,./src/3rdParty,./src/Mod/Assembly/App/opendcm,./src/CXX,./src/zipios++,./src/Base/swig*,./src/Mod/Robot/App/kdl_cp,./src/Mod/Import/App/SCL,./src/WindowsInstaller,./src/Doc/FreeCAD.uml,./build/doc/SourceDocu`
String List instead of String should allow for arbitrarily many entries,
theoretically.
Note the defaults previously in `YieldPoint1` an `YieldPoint2` were arbitrary.
Now the list is kept empty by default.
Fixes issue #4720.
Fixes two errors introduced in/due to 7621382272ae712ebf4493d996d1a1a918e95df7.
First one is a typo. The writer used "translations" where the reference file for
the test used "translation". Went with "translation" since that was mentioned in
the comment just above.
Second one is some missed out new lines in the reference file
`.../constraint_transform_beam_hinged.inp`. These lines were added in
`.../frequency_beamsimple.inp` but not here.