BIM: Compatibility fix for walls based on wire or face with -Z normal
In V1.0 the handling of wall normals has changed. As a result existing walls with their Normal set to [0, 0, 0], based on wires or faces with a shape normal pointing towards -Z, would be extruded in that direction instead of towards +Z as before. To avoid this their Normal property is changed to [0, 0, 1].
This commit is contained in:
@@ -216,9 +216,32 @@ class _Wall(ArchComponent.Component):
|
||||
def onDocumentRestored(self,obj):
|
||||
"""Method run when the document is restored. Re-adds the Arch component, and Arch wall properties."""
|
||||
|
||||
import DraftGeomUtils
|
||||
from draftutils.messages import _wrn
|
||||
|
||||
ArchComponent.Component.onDocumentRestored(self,obj)
|
||||
self.setProperties(obj)
|
||||
|
||||
# In V1.0 the handling of wall normals has changed. As a result existing
|
||||
# walls with their Normal set to [0, 0, 0], based on wires or faces with
|
||||
# a shape normal pointing towards -Z, would be extruded in that direction
|
||||
# instead of towards +Z as before. To avoid this their Normal property is
|
||||
# changed to [0, 0, 1].
|
||||
if FreeCAD.ActiveDocument.getProgramVersion() < "0.22" \
|
||||
and obj.Normal == Vector(0, 0, 0) \
|
||||
and hasattr(obj.Base, "Shape") \
|
||||
and not obj.Base.Shape.Solids \
|
||||
and obj.Face == 0 \
|
||||
and not obj.Base.isDerivedFrom("Sketcher::SketchObject") \
|
||||
and DraftGeomUtils.get_shape_normal(obj.Base.Shape) != Vector(0, 0, 1):
|
||||
obj.Normal = Vector(0, 0, 1)
|
||||
_wrn(
|
||||
"v1.0, "
|
||||
+ obj.Label
|
||||
+ ", "
|
||||
+ translate("Arch", "changed 'Normal' to [0, 0, 1] to preserve extrusion direction")
|
||||
)
|
||||
|
||||
if hasattr(obj,"ArchSketchData") and obj.ArchSketchData and Draft.getType(obj.Base) == "ArchSketch":
|
||||
if hasattr(obj,"Width"):
|
||||
obj.setEditorMode("Width", ["ReadOnly"])
|
||||
|
||||
Reference in New Issue