[FEM] fix network pressure value display in result pipelines

was forgotten in https://github.com/FreeCAD/FreeCAD/commit/2b1bbd5e6c6
This commit is contained in:
Uwe
2022-03-28 02:25:19 +02:00
parent 784d62de10
commit 361ea3367d

View File

@@ -869,7 +869,7 @@ void FemVTKTools::exportFreeCADResult(const App::DocumentObject* result, vtkSmar
}
if (it->first.compare("DisplacementVectors") == 0)
factor = 0.001;
factor = 0.001; // to get meter
else
factor = 1.0;
@@ -922,10 +922,11 @@ void FemVTKTools::exportFreeCADResult(const App::DocumentObject* result, vtkSmar
|| (it->first.compare("PrincipalMax") == 0)
|| (it->first.compare("PrincipalMed") == 0)
|| (it->first.compare("PrincipalMin") == 0)
|| (it->first.compare("vonMises") == 0))
factor = 1e6;
|| (it->first.compare("vonMises") == 0)
|| (it->first.compare("NetworkPressure") == 0) )
factor = 1e6; // to get Pascal
else if (it->first.compare("DisplacementLengths") == 0)
factor = 0.001;
factor = 0.001; // to get meter
else