[FEM] fix specific heat of air
- also adjust values slightly according to various sources Since a factor 1000 is a big mistake and air is the most common gas, please commit this also for FC 0.19
This commit is contained in:
committed by
Bernd Hahnebach
parent
034397b1d2
commit
95ec662c38
@@ -1,19 +1,19 @@
|
||||
[General]
|
||||
Name = Air
|
||||
Description = Standard air properties at 20 Degrees Celsius and 1 atm
|
||||
Description = Dry air properties at 20 Degrees Celsius and 1 atm
|
||||
MolarMass = 28.965
|
||||
Father = Gas
|
||||
|
||||
[Fluidic]
|
||||
Density = 1.20 kg/m^3
|
||||
Density = 1.204 kg/m^3
|
||||
DynamicViscosity = 1.80e-5 kg/m/s
|
||||
KinematicViscosity = 1.511e-5 m^2/s
|
||||
; PrandtlNumber is a nondimension number for CFD simulation
|
||||
PrandtlNumber = 0.7
|
||||
|
||||
[Thermal]
|
||||
SpecificHeat = 1.005 J/kg/K
|
||||
ThermalConductivity = 0.0257 W/m/K
|
||||
SpecificHeat = 1.01 kJ/kg/K
|
||||
ThermalConductivity = 0.02587 W/m/K
|
||||
; volumetric expansion coeff of ideal gas depends on temperature and pressure
|
||||
VolumetricThermalExpansionCoefficient = 3.43e-3 m/m/K
|
||||
|
||||
|
||||