BIM: check if Width and Height of window are not zero
This commit is contained in:
@@ -51,10 +51,10 @@ def makeWindowPreset(windowtype,width,height,h1,h2,h3,w1,w2,o1,o2,placement=None
|
||||
w2 = float(w2)
|
||||
o1 = float(o1)
|
||||
o2 = float(o2)
|
||||
# h1, h2, w1, w2 cannot be null (for now)
|
||||
# width, height, h1, h2, w1, w2 cannot be null (for now)
|
||||
# TODO allow these to be null (don't create the component if so)
|
||||
if h1*h2*w1*w2 == 0:
|
||||
FreeCAD.Console.PrintError("H1, H2, W1 and W2 parameters cannot be zero. Aborting\n")
|
||||
if width*height*h1*h2*w1*w2 == 0:
|
||||
FreeCAD.Console.PrintError("Width, Height, H1, H2, W1 and W2 parameters cannot be zero. Aborting\n")
|
||||
return
|
||||
# small spacing to avoid wrong auto-wires in sketch
|
||||
tol = h1/10
|
||||
|
||||
Reference in New Issue